Model 2L760

Extremely accurate gas-independent fast-response transducer vacuum instrument

Model 2L760

Specifications
Power: 115 VAC, 60 Hz
Vac Interface: 1/8 inch MNPT, KF/NW, 3/32 O.D. hose barb
Sensor: Digivac 760T
Range: 0-760
Units: Torr (mm Hg)

The 2L760 is an accurate, rugged and reliable vacuum instrument for measuring vacuum in the Torr range.  It uses proven piezoelectric transducer technology combined with solid state electronics enclosed in vinyl clad metal packaging that results in a tough gauge. This gauge is available by default as an absolute gauge but is also available as a differential gauge in quite a few units: inches of water, inches of mercury or PSI.  The 2L760 follows a 1000 Torr capacitance manometer through it's range for about 1/3 the price.  This unit gives accurate repeatable results with thousands used in commercial and laboratory applications with a wide range of options to fit your needs such as RS232 and plotting software.  If you are working with clean gas and require accuracy within 2 Torr, the model 2L760 is for you

Vacuum instrumentation with everything you need to go to work

Each Digivac Vacuum Gauge comes with:

  • A vacuum gauge controller (the white box above)
  • A 760T vacuum gauge tube (that senses vacuum)
  • A cable to connect the vacuum gauge controller to the vacuum gauge tube
  • A line cord for a standard 100V wall outlet

Model 2L760 Data sheet

 

Optional Features and Prices


Description Options Qty Price

Model 2L760 $425.00

2C The units listed with Control have the ability to turn on an external device via two SPDT external connections allowing controls to be activated at two vacuum set-points. The relays activate at and remain on below the set-points $75.00

Cal Calibration of a Digivac Vacuum gauge against a NIST traceable standard - included on all new gauges $0.00

mBar Displays vacuum reading in mBar $0.00

5V5T Provides a voltage output proportional to vacuum reading which ranges from 0-5 volts at 1mV per mTorr (1 micron = 1 mV, 5 Torr = 5 Volts) $75.00

Differential Enables the instrument to measure or control in differential units instead of absolute units. Differential units supported are inches of mercury, inches of water and PSI. Please specify range and units when ordering $0.00

LBD A Linear by Decade scheme where the leading digit is scale, and the last digit is the vacuum reading. For example: 0.995 Volts = 0.995 Torr, 1.010V = 10.1T, 2.1V =100T, and 3.760V = 760T $75.00

NISTCal Calibration of a Digivac Vacuum gauge against a NIST traceable standard with data $190.00

Switch Reads an integer Torr reading (switch down) and Adds a decimal point allowing the gauge to indicate tenths of Torr below 199.9 and indicates off scale $50.00